Dual-Rate Force-Image Control with Model-Based Orientation Limits for Robotic Ultrasound
2610.05839

Authors

Qiang Zhang,A B M Tahidul Haque,Anh Thu Nguyen,Tyler Foster

Abstract

Robotic ultrasound couples a high-rate contact-force loop with slower, delayed image feedback, so image-guided ultrasound probe rotation can perturb contact force before the resulting image response is observed. We derive a closed-form orientation-rate limit that bounds the modeled rotation-induced estimated-force excursion over a finite horizon while accounting for disturbance rejection by the fast force loop.

The limit depends on local contact stiffness, force-loop gains, a conservative rotation-to-force gain bound, the excursion budget, and the prediction horizon. We implement this model in a dual-rate controller with timestamp-based delay reconstruction and joint-torque-based force estimation, and evaluate it on a curved gelatin phantom using paired controller comparisons and component ablations.

Relative to unconstrained image guidance, the proposed rate-limited controller reduced first-second root-mean-square (RMS) estimated-force error by 0.40 N while increasing cue-convergence time by 0.94 s. A fixed rate cap near the analytically predicted ceiling produced no resolvable difference in force error and converged 0.32 s faster, indicating that the principal practical value of the model is the rate-design rule rather than online prediction.

Delay reconstruction had no resolvable effect at the tested latency. A single-subject popliteal scan demonstrated feasibility, although the image cue was noise-limited on heterogeneous tissue.

Resources

Ray graphicRay graphicRay graphicRay graphic

Stay in the loop

Every AI paper that matters, free in your inbox daily.

Details

  • takara.ai
  • Custom AI and machine learning from the Frontier Research Team.
  • © 2026 takara.ai Ltd
  • Content is sourced from third-party publications.
Ray graphicRay graphicRay graphic